- Dosimetric Comparison and Evaluation of 4 Stereotactic Body ...🔍
- Towards personalised dosimetry in patients with liver malignancy ...🔍
- Analysis of the Effect of Edema on Dosimetric and Radiobiological ...🔍
- Dose|volume and radiobiological dependence on the calculation ...🔍
- Radiobiological analysis of VMAT treatment plan with flattened and ...🔍
- Automatic Radiobiological Comparison of Radiation Therapy Plans🔍
- Relationship between the Patients' Setup Errors with Dosimetric and ...🔍
- Evaluation of Treatment Plan Quality between Magnetic Resonance ...🔍
Evaluation of the dosimetric and radiobiological parameters in four ...
Dosimetric Comparison and Evaluation of 4 Stereotactic Body ...
The highest dose conformity was realized with RapidArc. The dose coverage of the planning target volume was lowest with noncoplanar intensity-modulated ...
Towards personalised dosimetry in patients with liver malignancy ...
Although the selection of accurate linear–quadratic model parameters is essential for the estimation of radiation response and treatment outcome ...
Analysis of the Effect of Edema on Dosimetric and Radiobiological ...
Conclusions: Values of various dosimetric parameters investigated in this study increased with increasing post-implant time and attains optimal values in 4 ...
Dose-volume and radiobiological dependence on the calculation ...
This is important in the treatment plan QA because most dose, dose-volume, and radiobiological parameters are calculated based on the DVHs of targets and organs ...
Radiobiological analysis of VMAT treatment plan with flattened and ...
By comparing both the physical dose parameters and radiobiological parameters between the FF and FFF VMAT treatment plans, the study aimed ...
Automatic Radiobiological Comparison of Radiation Therapy Plans
The isodose curves associated with 3D-CRT, IMRT and VMAT plans for gastric cancer are presented in Figure 4. The dose parameters for the PTV and eight different ...
Relationship between the Patients' Setup Errors with Dosimetric and ...
dosimetric and radiobiologic parameters (TCP and. NTCP) using various ... Radiobiological Evaluation. TCP and NTCP parameters were used for.
Evaluation of Treatment Plan Quality between Magnetic Resonance ...
All plans were normalized to cover 95% of the target volume by 100% of the prescribed dose. Dosimetric characteristics were evaluated for each ...
Dosimetric and radiobiological evaluation of treatment plan for ...
The correlation between dosimetric and radiobiological parameters was found statistically significant, which shows the influence of dosimetric parameters on the ...
Evaluation of Flattening-Filter-Free and Flattening Filter Dosimetric ...
... Dosimetric and Radiobiological Criteria for Lung SBRT: A Volume-Based Analysis ... parameters of PTV, lung and NTCP in four group according to the PTV volume ...
Dosimetric and radiobiological evaluation of treatment plan for ...
Conclusions: The correlation between dosimetric and radiobiological parameters was found statistically signifi- ... volume was divided into four ...
Impact of Dose Calculation Algorithms and Radiobiological ...
Background: Breast cancer requires evaluating treatment plans using dosimetric and biological parameters. Considering radiation dose distribution and tissue ...
Pol J Med Phys Eng 2019;25(1):35-41 - Sciendo
We evaluated and compared the radiobiological results of four ... dosimetric/radiobiological parameters, radiobiological findings approved the dosimetric results.
Radiobiological Dosimetry for SIRT - Journal of Nuclear Medicine
A dosimetric analysis that incorporated radiobiological parameters for 90Y was undertaken and the clinical implications reviewed. MATERIALS ...
Influence of physical and radiobiological models on evaluation of ...
Dosimetric and radiobiological evaluation metrics are estimated to compare the two plans in terms of TCP, NTCP, and P+ in the context of the ...
Evaluation of Dosimetric and Radiobiological Parameters for ...
In these treatment planning systems, plans were done by 6 MV photon energy using Volumetric Arc Therapy (VMAT) techniques. The prescribed dose ...
Comparison of various common whole pelvic radiotherapy (WPRT ...
All the WPRT and LRT procedures compared with each other based on the dosimetric parameters and radiobiological models. ... dosimetric and radiobiological ...
Dosimetric and radiobiological comparison of prostate VMAT plans ...
This study compared the dosimetric and radiobiological parameters of prostate volumetric modulated arc therapy (VMAT) plans using different prescriptions.
Impact of dose calculation models on radiotherapy outcomes and ...
However, based on DVH, the radiobiological modelling allows to evaluate the clinical outcome of treatment plans such as the tumor control probability (TCP) and ...
Dosimetric and radiobiological comparison of treatment plan ...
Analysis of dosimetric parameters associated with acute gastrointestinal toxicity and upper gastrointestinal bleeding in locally advanced pancreatic cancer ...