Why some electrical boxes have clamps for the Romex and others ...
Types of Electrical Boxes - The Home Depot
Junction Box: Wires connect only to each other, never to a switch, receptacle or fixture. Allows circuits to safely split and branch into different directions.
New ROMEX into old boxes - DoItYourself.com Community Forums
Electrical - AC & DC - New ROMEX into old boxes - OK so ... New metal boxes have a different style clamp. ... Some outlets are dead, others fine.
Residential Wiring - NM Cables in Fiberglass Boxes Without Clamps
Oh and I have another question to ask. In southern ontario everyone uses 30-30s... a PVC based connector for romex ... have some qualities of ...
2 Most Common Issues DIYers Make With Metal Electrical Boxes
With plastic, there is no risk of the box being electrified if something goes wrong. Sure, they will melt in a fire, but if it gets to that ...
Romex Clamps - Inside out? - ECN Electrical Forums
Box Fill can also be a item to cite, as the 'clamp' would have to be counted, along with any other clamps within the box. As you said ...
Outlet Boxes: clamps & gromets required? - HomeOwnersHub
The reason those holes are used is to allow connection of conduit as well as Romex and BX type cables. (you simply use a different clamp/ ...
Running Electrical Wire into Surface-Mounted Receptacle
You would use it on the outside of the box, to make the bend to enter the wall. You're not supposed to leave the cable exposed without physical ...
Metal Vs Plastic Electrical Boxes | Avoid This Common DIY Mistake
... boxes. There are a lot of advantages to metal boxes but you do need to have some knowledge to ensure you aren't making common DIY mistakes ...
Cable clamp...screws inside or outside the box? - GardenWeb
I'm adding a circuit to a subpanel and want to know if it matters, code-wise, which way the cable clamp for the Romex is mounted in the hole ...
Protecting NM Cables, Electrician Wiring Mistakes - YouTube
This is one of the reasons why I, as a home owner, hate doing simple electrical work on my house. Replace an outlet. Metal box with nothing ...
i want to run ROMEX into this PLASTIC BOX. is some KIND of WIRE ...
Welcome! What's going on with your electrical installation? Wire glandClamp necessityOthers.
Is it acceptable, or to code, to splice electrical wire outside of a ...
Splices need to be in a junction box, and the box needs to be accessible. If you are neat, all of your connections will be in junction boxes ...
Running romex inside of walls with a surface mount breaker box???
Any pictures of the box? You definitely need to use a clamp coming out of the box with romex .. Don't listen to anyone who tells you otherwise.
How to add Romex Cable to this Junction Box - element14 Community
I live in the US. I am trying to install an ac outlet in my attic. Attached is a metal junction box that looks like it has Romex cable ...
What wire clamp for 18 gauge wire? | Hearth.com Forums Home
They are buried in the sea of other electric bushings, fittings, etc ... They fit into the 1/2" knockout and have a ... Romex® is a Registered ...
OT - confused with BX cable and device boxes... - Practical Machinist
You've got it right, those are Romex boxes not BX. The difference is in the clamp like you thought. If you have some BX clamps around you could ...
Wires Doubled - Electrical Inspections - InterNACHI® Forum
Is it acceptable to use one knock-out opening and clamp for 2 wires going into a panel? How about 3 or 4 wires going through a hole drilled ...
Split Panel clamp? | The Garage Journal
... panel was missing a Romex connector clamp ... A Manards or Or electrical supply house will have these larger ones. ... others · You must log ...
Supporting Romex with Romex - ECN Electrical Forums
"Cable wiring methods shall not be used as a means of support for other cables,raceways,or nonelectrical equipment." If it's not being used as a ...
i am INSTALLING an ELECTRICAL BOX outside and it has ...
If the box is going to be mounted directly over the hole where the Romex exits that attic, you don't need a strain relief or a clamp as you can ...