Events2Join

A Novel Method for the Measurement of Serum Viscosity


A Novel Method for the Measurement of Serum Viscosity - RheoSense

Background: Measurement of serum viscosity is used to evaluate. Hyperviscosity Syndrome (HVS), which is associated with plasma.

Microcantilever based disposable viscosity sensor for serum and ...

The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a resolution better than ...

Microcantilever based disposable viscosity sensor for serum and ...

The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a ...

A novel approach to blood plasma viscosity measurement using ...

Molecular rotors, a group of fluorescent molecules with viscosity-dependent quantum yield, were tested for their suitability to act as fluorescence-based ...

(PDF) Microcantilever Based Disposable Viscosity Sensor for Serum ...

devices are important for measuring viscosity of biological fluids. 5. Conclusion. A new method to measure the blood plasma viscosity with high. precision is ...

Microcantilever based disposable viscosity sensor for serum and ...

nient novel measurement method for measuring blood plasma and serum viscosity from low sample volumes with a high sensitivity. There are ...

A novel approach to blood plasma viscosity measurement using ...

The viscosity of samples of human plasma was modified by the addition of pentastarch (molecular mass 260 kDa, 10% solution in saline) and measured with a ...

Simplified Method for Estimation of Serum and Plasma Viscosity in ...

Based on these observations, a rapid screening test for the measurement of serum or plasma viscosities was described. Previous article ...

Clinical Laboratory Measurement of Serum, Plasma, and Blood ...

Abstract. This article discusses the fundamentals for measuring the viscosity of whole blood, serum, and plasma and its application to the diagnosis of hyp.

[PDF] Microcantilever based disposable viscosity sensor for serum ...

A fully automated cantilever-based method for highly precise and sensitive measurements of microliter sample volumes of human blood plasma coagulation.

A novel approach to blood plasma viscosity measurement using ...

A novel approach to blood plasma viscosity measurement using fluorescent molecular rotors. MARK A. HAIDEKKER,1 AMY G. TSAI,1 THOMAS BRADY,2 HAZEL Y. STEVENS ...

Plasma viscosity: Evaluation of a new measuring method using ...

MicroVisc™ is suitable for measuring plasma viscosity in a clinical setting and results can be evaluated using the established reference range.

Viscosity Measurement Sensor: A Prototype for a Novel Medical ...

Since the amount of available biological samples is usually scarce, common viscosity measurement techniques include capillary viscometers or ...

A novel approach to blood plasma viscosity measurement using ...

Recently, the molecular rotors are widely used to probe viscosity changes in complex biological samples including cytoplasm [10][11][12][13][14] ...

A novel approach to blood plasma viscosity measurement using ...

The results show the suitability of molecular rotors for fast, low-volume biofluid viscosity measurements achieving accuracy and precision comparable to ...

Optoelectronic microfluidic device for point-of-care blood plasma ...

This study presents a precise, non-contact optoelectronic system using a microfluidic platform for the measurement of blood plasma viscosity.

(PDF) Microcantilever based disposable viscosity sensor for serum ...

The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a resolution better than ...

Measurement of plasma viscosity by free oscillation rheometry

Traditionally, routine measurement of serum or PV has been performed using a manual capillary viscometer, e.g. the Ostwald viscometer in which ...

Standardization for obtaining blood viscosity: A systematic review

The acquisition time is related to the equipment used. BV measurements at 37°C will represent the real BV in vivo more faithfully. In order to ...

Viscosity, Serum - UW Laboratory Test Guide

Results are reported as a relative viscosity to water, where normal serum and plasma have a relative viscosity of up to 1.6. Although viscosities >1.6 are ...