Accurate component positioning and planning is vital to prevent malalignment of total knee arthroplasty (TKA) as malalignment is associated with an ...

Accuracy of Bone Resection in MAKO Total Knee Robotic-Assisted ...

The accuracy in achieving preoperatively planned bone resection and final limb coronal alignment using the MAKO Total Knee system is high.

Evaluating the accuracy of a new robotically assisted system in ...

Robot-assisted total knee arthroplasty (TKA) has been shown to facilitate high-precision bone resection, which is an important goal in TKA.

Accuracies of bone resection, implant position, and limb alignment ...

This study assessed the accuracy of robotic-arm-assisted total knee arthroplasty (RATKA) for bone resection, component size prediction, implant placement, and ...

Comparative assessment of current robotic-assisted systems in ...

Robotic-assisted total knee arthroplasty (TKA) has proven higher accuracy, fewer alignment outliers, and improved short-term clinical ...

Robot-assisted total knee arthroplasty improves mechanical ...

Patients in the MAKO group achieved better accuracy than those in the conventional group in terms of postoperative mean mechanical axis (1.9˚ vs ...

Mako Total Knee arthroplasty: clinical summary | Stryker

2020 Mar 4. 26. Sire JD, Craik JD, Wilson CJ. Accuracy of Bone Resection in MAKO Total. Knee Robotic-Assisted Surgery. J Knee ...

The accuracy of bone resections made during computer navigated ...

For 89 patients undergoing primary TKR, the bone cut from the distal femur and proximal tibia was measured using Vernier callipers and compared to the computer ...

Comparison of the efficacy and safety of MAKO robot-assisted total ...

found in a prospective cohort study that compared to traditional total knee arthroplasty, robot-assisted TKA resulted in less bone and soft ...

High accuracy of a new robotically assisted technique for total knee ...

The results of this study demonstrated that using this new surgical robot in total knee arthroplasty it is possible to perform accurate bone cuts.

Robotic arm-assisted total knee arthroplasty improves preoperative ...

A preoperative accuracy of 97% for predicting the size of the femoral component and 93% for the tibial component allows the surgical team to ...

Accuracy of Bone resection in the MAKO robotic knee system in ...

In the robotic group, the accuracy of all of the bone resection levels was below 0.6 mm (with SDs below 0.6 mm), and all of the bone resection angles were below ...

Total Knee Replacement with Mako Robotic-Arm Assisted ... - Stryker

Deckey DG, Rosenow CS, Verhey JT, et al. Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques. Bone ...

Robotic arm-assisted total knee arthroplasty in a patient with ...

RA-TKA offers several advantages, such as no requirement of intramedullary guides and the use of thicker saw blades, resulting in accurate bony ...

My Transition from Mako® to NAVIO™ and finally to the ROSA ...

For the ROSA Knee-assisted knees, the accuracy of bone resection ... “Robotic Surgery in Total Joint Arthroplasty: A Survey of the AAHKS ...

Comparison of Alignment Accuracy and Clinical Outcomes between ...

The MAKO and the ROSA had similar accuracy and precision in coronal alignment in total knee arthroplasty (TKA). The clinical outcomes at 1 ...

Accuracy of Bone Resection in MAKO Total Knee Robotic-Assisted ...

In total, 99 out of 105 (94.29%) of bone resections were within 1mm of the plan. Mean absolute difference in final limb coronal alignment was 0.78° (0.78), with ...

Mako Robotic-Arm Assisted Total Knee Arthroplasty - JOMI

Therefore, robotic-assisted total knee arthroplasty (RATKA) may increase the accuracy of bone cuts and component placement. In another ...

Accuracy of Bone Resection in MAKO Total Knee Robotic-Assisted ...

“…The accuracy of the proposed method is promising with ≤ 1 mm deviation to a 3D scan. These error Table 3 Radiographic measurements values are within clinical ...

Robotic Systems in Knee Surgery: Current Concepts and Future ...

According to recent studies, this new technology is highly precise and accurate, predicting the implant size in 93.1% of the cases (higher than ...