Events2Join

Accuracy of acetabular cup placement during anterolateral supine ...


Accuracy of acetabular cup placement during anterolateral supine ...

Abstract. Background: In our institution, total hip arthroplasty (THA) is performed using the anterolateral supine (ALS) approach with ...

Accuracy of acetabular cup placement during anterolateral supine ...

This study aimed to investigate and review the accuracy of acetabular cup placement in ALS-THA using intraoperative fluoroscopy.

Accuracy of Acetabular Cup Placement During Total Hip ...

Accurate cup placement during total hip arthroplasty (THA) is difficult because the intraoperative pelvic position changes even in supine patient position.

Measurement accuracy of the acetabular cup position using ... - Nature

Accurate cup placement with portable hip navigation systems in the supine position has already been reported. In previous study of portable hip ...

Accuracy of acetabular cup insertion in an anterolateral supine ...

The mean postoperative radiographic inclination and anteversion relative to the APP in the navigation group were 38.0° ± 4.0° (range 30.6°–47.9°) ...

Accuracy of acetabular cup placement in total hip arthroplasty using ...

The percentage of acetabular cups placed within ±5° from the target angles was significantly higher in the Pin-less AR navigation group (90.3%) compared with ...

(PDF) Accuracy of acetabular cup placement during anterolateral ...

The cup position angle was measured using postoperative computed tomography, and the error in the target angle was investigated. Results The target angle of RI ...

Accuracy of acetabular cup placement during anterolateral supine ...

The accuracy of cup placement using various portable navigation systems in the lateral decubitus position is 2.5°–4.6° for RI and 2.3°–6.5° for RA [ 4 , 14 ].

Accuracy of acetabular cup placement during anterolateral supine ...

Background: In our institution, total hip arthroplasty (THA) is performed using the anterolateral supine (ALS) approach with intraoperative fluoroscopy. This ...

Registration in the supine position improve the accuracy of cup ...

investigated acetabular component orientation in 834 primary THAs using the manual technique in the lateral decubitus position and revealed that ...

Accuracy of acetabular cup insertion in an anterolateral supine ...

The mean absolute error for anteversion was 3.3° in the navigation group and 5.9° in the control group (P < 0.001). The mean absolute values of navigation error ...

Supine versus lateral position for accurate positioning of acetabular ...

In this randomized-controlled trial, higher accuracy of acetabular cup inclination was provided by supine position than by lateral position in THA.

Accuracy of acetabular component alignment with surgical guidance ...

The mean (and standard deviation) of the absolute difference between the postoperative CT and the intra-operative measurements for inclination ...

Accuracy of cup orientation and learning curve of the accelerometer ...

The average absolute error in measurement (postoperative CT-navigation record) was 2.6° ± 2.7° (inclination) and 2.8° ± 2.7° (anteversion). The ...

Acetabular Placement Accuracy With the Direct Anterior Approach ...

... cup placement in the supine position via the anterolateral approach. They found a 25.7% rate of safe zone placement. Hassan et al [21] ...

Decreased accuracy of acetabular cup placement for imageless ...

Imageless navigation can be performed with an error of approximately 3° at the anterior pelvic plane. However, accuracy was found to decrease in obese cases.

(PDF) Accuracy of Acetabular Cup Placement During Total Hip ...

Conclusions HipPointer is simple in structure, easy to use, and useful for direct-anterior-approach THA in supine position. It provides good cup placement ...

Accuracy of Cup Placement Angle, Leg Lengthening, and Offset ...

... position assessed by AR Hip. The S group consisted of 15 patients (17 hips, 5 males) who underwent THA via the anterolateral approach in the supine position.

Accuracy of acetabular cup placement during anterolateral supine ...

Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study. Language ...

Accuracy of Cup Positioning With the Computed Tomography-Based ...

Accuracy of acetabular cup insertion in an anterolateral supine approach using an accelerometer-based portable navigation system · Engineering, Medicine. Journal ...