- Aerodynamic Performance of Air Cooled Condensing Units🔍
- Performance prediction of an air|cooled steam condenser using ...🔍
- Mitigation Of Wind Effect On Air Cooled Condenser Performance🔍
- Getting top performance from your air|cooled condenser🔍
- Cooling Performance Enhancement of Air|Cooled Condensers by ...🔍
- Energy|efficient operation of a direct air|cooled condenser based on ...🔍
- Aerodynamic numerical calculations of air|cooled condensers and ...🔍
- A Review on Performance Analysis of Air|Cooled Condenser under ...🔍
Aerodynamic Performance of Air Cooled Condensing Units
Aerodynamic Performance of Air Cooled Condensing Units
... Aerodynamic Performance of Air Cooled Condensing Units" (2006). International Refrigeration and Air Conditioning Conference. Paper 766. http://docs.lib ...
Aerodynamic Performance of Air Cooled Condensing Units
By Claudio Melo, Gustavo Pottker, and Robert H. Pereira, Published on 01/01/06.
Performance prediction of an air-cooled steam condenser using ...
It is found that wind speed has great influences on the performance of air-cooled steam condensers due to the variation of pressure distribution around the ACSC ...
Mitigation Of Wind Effect On Air Cooled Condenser Performance
Data was filtered to similar ambient temperature and unit heat load, over wide range of wind velocities in order to experimentally obtain the direct wind effect ...
Getting top performance from your air-cooled condenser
Air-side performance is evaluated based on the temperature rise of the coolant across the finned heat-exchanger tubes. The hot air temperature is commonly ...
Cooling Performance Enhancement of Air-Cooled Condensers by ...
The results show that, with the guidance of deflectors, reverse flows are obviously suppressed in the upwind condenser cells under windy conditions.
Energy-efficient operation of a direct air-cooled condenser based on ...
The aerodynamic behavior of the fans array of the direct air-cooled condenser is different from that of a single fan because of the interaction effect ...
Aerodynamic numerical calculations of air-cooled condensers and ...
Results of a research of the combined operation of fans and V-shaped heat exchangers by methods of numerical model operation at wind and without it for three- ...
A Review on Performance Analysis of Air-Cooled Condenser under ...
It is observed that rise in wind velocity decreases thermal effectiveness of Air-Cooled Condenser-ACC up to considerable level. Ambient temperature not only ...
Performance Forecast of Air-Cooled Steam Condenser under Windy ...
It is found that the negative pressure region under the ACSC platform results in volumetric effectiveness reduction of the windward fans with increasing wind ...
AIR-COOLED CONDENSERS: Chemistry, corrosion, performance ...
A fogging mist is released into the air flowing through the fans and tube bundles. The mist evaporates quickly, cooling the air. The only requirement is a ...
Energy-Efficient Operation of a Direct Air-cooled Condenser Based ...
For example, the air-cooled condenser has low cooling efficiency, high fan energy consumption, and is sensitive to environmental factors ( ...
(PDF) Cooling Performance Enhancement of Air ... - ResearchGate
The results show that, with the guidance of deflectors, reverse flows are obviously suppressed in the upwind condenser cells under windy ...
Experimental study and analysis of an air-cooled condenser with the ...
The paper presents the results of a theoretical and experimental study aimed at improving the efficiency of commercial refrigeration systems.
Aerodynamic performance of air-cooled condensing... | 17/07/2006
The aerodynamic performance of two condensing units is investigated in the paper. A testing facility was built according to AMCA 210-99 and used to evaluate ...
Fans for condensers in refrigeration technology - ebm-papst
Axial fans are usually used to direct air at the fins of the heat exchanger in the condenser, dissipating the heat. In this process, the refrigerant is cooled ...
Development of High Efficiency Air Conditioner Condenser Fans
Air-cooled condensers in residential air conditioning (AC) systems commonly employ finned-tube construction to transfer heat from the refrigerant to the outdoor ...
Turbine Aerodynamic Performance Measurement Under ...
With the engine representative gas-to-wall ratio in the ORF, the HP stage exit flow is at almost ambient conditions, as such, the IPV heat transfer is ...
Danfoss adapts condensing unit to better fit G&D Chillers' needs
The basic design of a heat exchanger is crucial in determining its performance. Traditional air-cooled condensers, called round tube and plate ...
Aerodynamic performance enhancement of centrifugal compressor ...
The primary objective of this research is to comprehensively investigate and improve the aerodynamic performance of centrifugal compressors.