Events2Join

Comparison of Upright Digital Breast Tomosynthesis–guided versus ...


Comparison of Upright Digital Breast Tomosynthesis–guided versus ...

Conclusion. Upright digital breast tomosynthesis–guided vacuum-assisted breast biopsy has a higher rate of technical success than does prone ...

Comparison of Upright Digital Breast Tomosynthesis-guided versus ...

Purpose To compare the performance of upright digital breast tomosynthesis (DBT)-guided vacuum-assisted breast biopsy (VABB) with that of ...

Comparison of Upright Digital Breast Tomosynthesis–guided versus ...

Purpose: To compare the performance of upright digital breast tomosynthesis (DBT)–guided vacuum-assisted breast biopsy. (VABB) with that of prone stereotactic ( ...

Prone Versus Upright Digital Tomosynthesis–Guided Biopsy | AJR

Digital breast tomosynthesis (DBT) is being increasingly used in clinical practice because several studies have shown that it increases cancer ...

Prone Versus Upright Digital Tomosynthesis–Guided Biopsy

The objective of our study was to compare the performance of digital breast tomosynthesis (DBT)-guided prone and upright breast biopsies.

Comparison of Upright Digital Breast Tomosynthesis-guided versus ...

Upright digital breast tomosynthesis-guided vacuum- assisted breast biopsy has a higher rate of technical success than does prone stereotactic ...

Prone Versus Upright Digital Tomosynthesis-Guided Biopsy - PubMed

OBJECTIVE. The objective of our study was to compare the performance of digital breast tomosynthesis (DBT)-guided prone and upright breast ...

Comparison of Upright Digital Breast Tomosynthesis–guided versus ...

42). No major complications were observed in either group. Conclusion Upright digital breast tomosynthesis-guided vacuum-assisted breast biopsy has a higher ...

Digital Mammography Stereotactic Biopsy versus Digital Breast ...

n Digital breast tomosynthesis–guided biopsy versus digital mam- mography ... Comparison of Upright Digi- tal Breast Tomosynthesis-guided versus Prone ...

Upright Digital Breast Tomosynthesis-Guided Breast Biopsy

Upright DBT VAB is proving to be a faster and more comfortable method to biopsy patients compared to prone stereotactic table VAB. Several trials have ...

Implementation of Upright Digital Breast Tomosynthesis-guided ...

Compared to FFDM alone, FFDM plus DBT has been shown to increase the cancer detection rate, detect smaller cancers, and reduce the rate of false-positive ...

A comparison of stereotactic and tomosynthesis‐guided localisation ...

94.8% of the seeds and wires inserted via prone stereotactic guidance were accurately placed, compared with 89.6% of those inserted via upright ...

Clinical performance of digital breast tomosynthesis–guided vacuum ...

The tissue sampling success rate was 95.6% for ST-VAB (43/45) and 97.7% (84/86) for DBT-VAB. Time for positioning (10.6 ± 6.4 vs. 6.7 ± 5.3 min) ...

Retrospective Comparison of the Lateral-Arm and Vertical Needle ...

Recall and cancer detection rates improve with digital breast tomosynthesis (DBT) because it resolves summation artifacts and highlights subtle ...

Comparing digital breast tomosynthesis-guided radioactive seed ...

Madeley et al compared prone stereotactic-guided wire or seed localization to upright tomosynthesis wire or seed localization. Page 5. 4 and reported that ...

(PDF) Clinical benefits of tomosynthesis-guided vacuum assisted ...

Conclusion Our study demonstrated that the clinical performance of 3D-VAB is superior to that of 2D-VAB and that the significant reduction in examination time ...

Digital breast tomosynthesis-guided vacuum-assisted breast biopsy ...

Technical success was achieved in 51 of 51 lesions (100%) with DBT VAB versus 154 of 165 lesions (93%) with PS VAB. In one of 11 lesions in which PS VAB failed, ...

Transition to digital breast tomosynthesis‐guided biopsies: Results ...

Targeting success was similar for DBTB (99%) and PSBB (99%). DBTB was used to target both calcifications (110) as well as non‐calcified targets ...

Diagnostic accuracy of tomosynthesis-guided vacuum assisted ...

This study aims to evaluate the diagnostic accuracy of digital breast tomosynthesis-guided vacuum assisted breast biopsy (DBT-VABB) of ...

Upright Digital Breast Tomosynthesis-Guided Breast Biopsy

Upright DBT VAB is proving to be a faster and more comfortable method to biopsy patients compared to prone stereotactic table VAB.