- Comparison of antibody titers using conventional tube technique ...🔍
- Comparison of ABO antibody titers using the conventional tube ...🔍
- Comparative study of ABO antibody titers using conventional tube ...🔍
- Comparison of IgG ABO Antibody Titers using Conventional Tube ...🔍
- Comparison of Total and IgG ABO Antibody Titers in Healthy ...🔍
- Obstetric Antibody Titers🔍
- Comparative Evaluation of Titer Estimation of ABO Isoagglutinins ...🔍
- Comparison of antibody titers obtained using the IS tube and AHG ...🔍
Comparison of antibody titers using conventional tube technique ...
Comparison of antibody titers using conventional tube technique ...
CONCLUSION: The column agglutination method for anti A/B titer estimation in an ABO incompatible kidney transplant is more sensitive, with the column ...
Comparison of antibody titers using conventional tube technique ...
The column agglutination method for anti A/B titer estimation in an ABO incompatible kidney transplant is more sensitive, with the column agglutination ...
Comparison of ABO antibody titers using the conventional tube ...
The anti-A and anti-B titers were tested by two methods simultaneously. This process is shown in Figure 2. Conventional tube test (Routine blood bank laboratory ...
Comparative study of ABO antibody titers using conventional tube ...
Accept median of IgM anti-A in B and IgG anti-A and anti-B in O blood group by the two techniques were not statistically significant difference (Table 2). It ...
Comparison of antibody titers using conventional tube technique ...
The column agglutination method for anti A/B titer estimation in an ABO incompatible kidney transplant is more sensitive, with the column aggLutination ...
Comparison of antibody titers using conventional tube technique ...
Conclusion: The column agglutination method for anti A/B titer estimation in an ABO incompatible kidney transplant is more sensitive, with the ...
Comparison of IgG ABO Antibody Titers using Conventional Tube ...
The HDM can be used to perform IAT for determination of IgG ABO antibody titers in order to eliminate washing step and provides reliable results and ...
Comparison of Total and IgG ABO Antibody Titers in Healthy ...
Antibody titrations were performed using the immediate spin (IS) tube, anti-human globulin (AHG) tube, and CAT with or without DTT methods.
Obstetric Antibody Titers: A Comparison of Automated Gel ...
Automated gel methodology is associated with higher obstetric alloantibody titers than conventional tube method using the same patient ...
Comparative Evaluation of Titer Estimation of ABO Isoagglutinins ...
IgG titers were higher than IgM titers in most group O individuals. This difference was more evident with the use of CAT. The correlation between CTT and CAT ...
Comparison of antibody titers obtained using the IS tube and AHG ...
Park et al. compared only IgG titers of CTT with CAT and found that for blood group O, the titers were more in CAT than CTT. [32] ...
Antibody Titers in Transfusion Medicine: A Critical Reevaluation of ...
For anti-A, 5680 total titer responses were evaluated, with 3017 responses (53.1%) using the uniform procedure (tube, 2497 of 3017 [82.8%]; gel, ...
Comparison of the conventional tube and erythrocyte-magnetized ...
Different red blood cell blood group antibody titers were simultaneously detected using the tube polybrene test, tube antiglobulin test (AGT), ...
Comparison of gel test and conventional tube test for... - Sciendo
The samples were tested separately by the conventional tube technique and the gel test for antibody detection and titration. The tube test ...
Comparing red cell alloantibody detection and titration by gel ...
Conventional Tube Testing (CTT) method is widely accepted for antibody titration in antenatal cases but it can be replaced by Gel ...
Comparison of automated solid phase versus manual saline indirect ...
While SIAT is considered the gold standard method for determining perinatal antibody titers, this method has some disadvantages: It is a manual ...
A Prospective Observational Study to Compare ABO...
When determining ABO antibody titers, IgG antibodies can be masked by immunoglobulin M (IgM) antibodies. Hence, the measurement of actual concentration of IgG ...
Laboratory support of ABO antibody monitoring for ABO ...
Blood group antibodies are conventionally measured as titers using the two-fold dilution method. Titration is a method wherein the amount of ...
Comparison of the tube test and column agglutination techniques for ...
Currently, the recommended method for antibody titration is the tube test (TT) assay. Dithiothreitol (DTT) is used for IgM antibody inactivation ...
Impact of Uniform Methods on Inter-laboratory Antibody Titration ...
... titers of antibody with the gel in comparison with tube techniques in the absence of robust evidence linking gel titer levels with clinical outcomes could.