- Diagnostic performance of 18 F‑DCFPyL PET vs. 68 Ga‑PSMA PET ...🔍
- Diagnostic performance of 18F‑DCFPyL PET vs. 68Ga‑PSMA PET ...🔍
- Comparison of 18 F|based PSMA radiotracers with [ 68 Ga ...🔍
- Comparison of 18F|DCFPyL and 68Ga|PSMA|11 for ...🔍
- Diagnostic Performance of 18F|DCFPyL|PET/CT in Men with ...🔍
- The diagnostic performance of 18 F|DCFPyL PET in patients with ...🔍
- [PDF] Diagnostic performance of 18F‑DCFPyL PET vs. 68Ga‑PSMA ...🔍
- Diagnostic Performance of PSMA|based 18F|DCFPyL PET/CT in ...🔍
Diagnostic performance of 18F‑DCFPyL PET vs. 68Ga‑PSMA PET ...
Diagnostic performance of 18 F‑DCFPyL PET vs. 68 Ga‑PSMA PET ...
The pooled sensitivity and specificity of 18F-DCFPyL PET were 0.92 (95% CI, 0.85-0.96) and 0.59 (95% CI, 0.08-0.96), respectively. For 68Ga-PSMA ...
Diagnostic performance of 18F‑DCFPyL PET vs. 68Ga‑PSMA PET ...
The diagnostic performance of 18F-DCFPyL PET and 68Ga-PSMA PET/CT for primary PCa was examined by 13 studies included, comprising 1,178 patients ...
Diagnostic performance of 18 F‑DCFPyL PET vs. 68 Ga‑PSMA PET ...
F‑DCFPyL PET and 68Ga‑PSMA PET/CT both had an area under the receiver operating characteristic curve of 0.92 (95% CI, 0.89‑0.94). In addition, ...
Comparison of 18 F-based PSMA radiotracers with [ 68 Ga ... - Nature
Overall, [18F]DCFPyL was observed to have a similar lesion detection rate to [68Ga]Ga-PSMA-11 with no increase in false positive rates. [18F] ...
Comparison of 18F-DCFPyL and 68Ga-PSMA-11 for ... - Frontiers
VISION and TheraP trials used 68Ga-PSMA-11 PET for their ... Diagnostic performance and safety of positron emission tomography with 18F ...
Diagnostic Performance of 18F-DCFPyL-PET/CT in Men with ...
However, a recent multicenter prospective study of PET/CT using 68Ga-PSMA-11 did show that negative or prostate-bed-only positive findings were highly ...
The diagnostic performance of 18 F-DCFPyL PET in patients with ...
In clinical practice, the most commonly used positron nuclide was 18F-DCFPYL. It is based on a glutamate-urea-lysine structure. When compared with 68Ga-PSMA-11, ...
[PDF] Diagnostic performance of 18F‑DCFPyL PET vs. 68Ga‑PSMA ...
A comparable diagnostic performance for patients with suspected PCa was determined for 18F-DCFPyL PET and 68Ga-PSMA PET/CT and it is crucial to keep in mind ...
Diagnostic Performance of PSMA-based 18F-DCFPyL PET/CT in ...
There were 49 positive (51%) and 47 negative 18F-DCFPyL PET/CTs (49%). Detection rate at PSA ≤ 0.1, 0.2 ng/ml were 58.7% (27/46), 44% (22/50), ...
The differential diagnostic value of dual-phase 18F-DCFPyL PET/CT ...
Uptake of 18F-DCFPyL increased over time in prostate-associated malignant lesions compared with benign tissue. For single-phase imaging, 2-hour ...
PSA-Stratified Performance of 18F- and 68Ga-PSMA PET in Patients ...
Conclusion: Our data suggest that 18F-DCFPyL is noninferior to 68Ga-PSMA-HBED-CC, while offering the advantages of 18F labeling. Our results ...
18 F-PSMA-11 Versus 68 Ga-PSMA-11 Positron Emission ...
Based on the McNemar's test, no superiority of 18F-PSMA-11 over 68Ga-PSMA-11 could be concluded with respect to the number of positive PET scans ...
Invited Perspective PSMA-based 18F-DCFPyL PET
compared the performance of 18F-DCFPyL PET/CT and pelvic mpMRI in intermediate-high risk and biochemical recurrent prostate cancer patients. The ...
Diagnostic Accuracy of Ga-68 PSMA-11 PET/CT for Initial and ...
The radioactive PET imaging agent Ga-68 PSMA-11 has demonstrated higher PCa detection rates compared with conventional imaging techniques, ...
Intra-individual comparison of 68Ga-PSMA-11 and 18F-DCFPyL ...
This retrospective analysis included 34 patients with low tumor burden referred for PET/CT imaging with 68Ga-PSMA-11 and subsequently 18F-DCFPyL ...
F-DCFPyL-PET/CT in Men with Biochemically Recurrent Prostate ...
performance of the PSMA-targeted PET radiotracer 18F-DCFPyL for regulatory ... The diagnostic value of PET/CT imaging with the 68Ga-labelled PSMA.
Diagnostic Performance of 68 Ga Prostate-specific Membrane ...
Gallium 68 (68Ga) prostate-specific membrane antigen (PSMA) PET/MRI may improve detection of clinically significant prostate cancer (CSPC).
ASCO GU 2020: PSMA-targeted 18F-DCFPyL PET/CT Imaging in ...
Utilizing the PSMA protein in PET/CT prostate diagnosis is of interest given the limited utility of conventional 18F-FDG PET/CT. Available data ...
18 F-Fluciclovine versus PSMA PET Imaging in Primary Tumor ...
In the same clinical setting, fluorine 18–fluciclovine PET also enabled similar diagnostic accuracy for primary prostate cancer, with a pooled ...
Comparison of 68 Ga-PSMA-11 and 18 F-DCFPyL quantitative ...
Conclusion ¹⁸F-DCFPyL PET significantly affects the management of patients with prostate cancer. Higher PET positivity rate significantly correlated with a ...