- Differences in the setting of acetabular component alignment guides ...🔍
- Are Acetabular Component Alignment Guides for Total Hip ...🔍
- [PDF] Differences in the setting of acetabular component alignment ...🔍
- Accuracy of acetabular component alignment with surgical guidance ...🔍
- Mechanical and Anatomical Alignment Guide Techniques Are ...🔍
- Acetabular component alignment guide in total hip replacement🔍
- Determining the orientation of acetabular prosthesis in total hip ...🔍
- Is the alignment guide technique in total hip arthroplasty sufficient for ...🔍
Differences in the setting of acetabular component alignment guides ...
Differences in the setting of acetabular component alignment guides ...
This study aimed to compare the accuracy between modern acetabular component alignment guides for the lateral position and those for the supine position.
(PDF) Differences in the setting of acetabular component alignment ...
For supine position alignment guides, the inclination and anteversion indicated by the alignment guide itself were identical with those indicated by the ...
Are Acetabular Component Alignment Guides for Total Hip ...
The current study showed that the angles actually indicated and those stated by manufacturers were different. Such setting of alignment guides could result in ...
[PDF] Differences in the setting of acetabular component alignment ...
It was shown that the angles actually indicated and those stated by manufacturers were not identical for lateral position alignment guides, which is of ...
Are Acetabular Component Alignment Guides for Total Hip ...
In all the alignment guides, the angles actually indicated and those stated by manufacturers were different. Our results showed that usage of modern alignment ...
Accuracy of acetabular component alignment with surgical guidance ...
Positioning of the acetabular component is also greatly influenced by the patient's pelvic position during surgery. During a THA, the pelvis can ...
(Open Access) Differences in the setting of acetabular component ...
This study aimed to compare the accuracy between modern acetabular component alignment guides for the lateral position and those for the supine position.
Differences in the setting of acetabular component alignment guides ...
AbstractThe acetabular component orientation in total hip arthroplasty is of critical importance to clinical results. Although navigation systems and ...
Mechanical and Anatomical Alignment Guide Techniques Are ...
Correct orientation of the acetabular component (cup) in total hip arthroplasty (THA) is important to avoid instability, impingement, and excessive wear [[1], [ ...
Differences in the setting of acetabular component alignment guides ...
Differences in the setting of acetabular component alignment guides between the supine and lateral positions for total hip arthroplasty. Sci. Rep. Pub Date ...
Are Acetabular Component Alignment Guides for Total Hip ...
Such setting of alignment guides could be one of the factors of error in acetabular component orientation. ResearchGate Logo. Discover the world's research. 25 ...
Acetabular component alignment guide in total hip replacement | PPT
Methods of setting the acetabular component lateral position Alignment guides Design • line A should be.
Determining the orientation of acetabular prosthesis in total hip ...
The optimal cup anteversion could be obtained when the inferior edge of the acetabular cup was parallel to the PLAPAN (the mean anteversion was ...
Is the alignment guide technique in total hip arthroplasty sufficient for ...
Cup setting with only an alignment guide has been reported to be inaccurate in the lateral decubitus position in total hip arthroplasty ...
Are Acetabular Component Alignment Guides for Total Hip ... - CoLab
... increase by a mean of 2 degrees (maximum: 4 degrees ). Such setting of alignment guides could be one of the factors of error in acetabular component orientation
Patient-specific instrumentation improves the accuracy of acetabular ...
Accurate placement of the acetabular component can be achieved using patient-specific guides and is superior to free hand techniques and ...
Direct Anatomic Registration in Computer-Assisted Total Hip ...
The acetabular cup alignment in the study group was within the Lewinnek safe zone more than that in the control group (81.5% vs 59.6%, P < .05).
Cup placement in primary total hip arthroplasty: how to get it right ...
There are different methods to guide the placement of the acetabular component using anatomic landmarks without the need for special instruments ...
Improving the Accuracy of Acetabular Component Orientation
... guide placement of the acetabular component ... Digioia AM III, Jaramaz B, Plakseychuk. AY, et al: Comparison of a mechanical acetabular alignment guide with.
acetabular cup orientation system - Product Classification - FDA
The guide is used to place an alignment pin at/near the acetabular rim in a pre-operatively desired orientation. The alignment pin is used as a visual ...