The applications of Type B [anisotropic analytical algorithm (AAA) and collapsed cone (CC)] and Type C [Acuros XB (AXB) and photon Monte ...

Dosimetric verification of four dose calculation algorithms for spine ...

The phantom study showed that the results from AXB and PMC agreed with the measurements within ±2.0%. However, the mean dose difference ranged from 0.5 to 1 Gy.

Dosimetric verification of four dose calculation algorithms for spine ...

Dosimetric verification of four dose calculation algorithms for spine stereotactic body radiotherapy. Hideaki Hirashima1,*, Mitsuhiro ...

(PDF) Dosimetric verification of four dose calculation algorithms for ...

All treatment plans were created using AXB in Eclipse. The prescription dose was 24 Gy in two fractions at a 10 MV FFF on TrueBeam. The doses ...

[PDF] Dosimetric verification of four dose calculation algorithms for ...

The behavior of the dose distribution on the helical diode array differed depending on the dose calculation algorithm for small targets, and Measurements ...

Assessment of four dose calculation algorithms using IAEA ...

This study discusses the measurement of dose in clinical commissioning tests described in IAEA-TECDOC-1583. It explores the application of Monte Carlo (MC) ...

Verification of four-dimensional photon dose calculations - PubMed

Doses were calculated in the treatment planning system using the 4D dose calculation algorithm. Then each plan was delivered to the phantoms and delivered doses ...

Verification of four‐dimensional photon dose calculations

The author concluded that if patient breathing is reproducible, the 4D dose calculations are accurate to within clinically acceptable standards.

(PDF) Comparison of four commercial dose calculation algorithms in ...

Background: Accurate and fast dose calculation is crucial in modern radiation therapy. Four dose calculation algorithms (AAA, AXB, CCC, ...

End-to-End Verification and Dosimetric Comparative Study of ...

We commissioned the Brainlab Monte Carlo Dose Calculation Algorithm for VMAT SRS planning and verified it by measurements and comparisons with two other ...

Dosimetric verification of four dose calculation algorithms for spine ...

All treatment plans were created using AXB in Eclipse. The prescription dose was 24 Gy in two fractions at a 10 MV FFF on TrueBeam. The doses were then ...

Dosimetric verification of the anisotropic analytical algorithm for ...

In a homogeneous medium, agreement was found to be within 2% dose or 2mm dta in most instances. In the presence of heterogeneities, agreement was generally to ...

A Practical Method to Evaluate and Verify Dose Calculation ...

The plans were delivered and the actual doses were measured using radiation dosimetry devices MapCheck, EDR2-film, and ionization chamber respectively. Measured ...

Dosimetric verification of the anisotropic analytical algorithm for ...

In this study we have investigated the accuracy of dose calculations performed with the Anisotropic Analytical Algorithm in a range of situations from single ...

Dose Calculation Algorithms for External Radiation Therapy - MDPI

Among the features that have undergone a huge evolution in recent decades, dose calculation algorithms are still rapidly changing. This process ...

Dosimetric evaluation of Acuros XB Advanced Dose Calculation ...

The new Acuros XB algorithm implemented in the Varian Eclipse treatment planning system was compared against a Monte Carlo method (VMC++), and ...

[PDF] Dosimetric comparison of Acuros XB with collapsed cone ...

Compared with the recent Eclipse Acuros XB (AXB) dose calculation engine, the CCC algorithm was used for stereotactic ablative radiotherapy (SAbR) treatment ...

Accuracy of the Small Field Dosimetry Using the Acuros XB Dose ...

Furthermore, two clinical cases of arc deliveries were used to test the accuracy of the dose calculation algorithms against MC. Results: Open field tests in a ...

Dosimetric verification of a commercial collapsed cone algorithm in ...

Nominal 4, 6 and 15MV photon beams were studied. Results. For most homogeneous cases agreement between measured and calculated dose is within ±2% or ±2mm. In ...

Comparison of four commercial dose calculation algorithms in ...

Hartman Siantar, Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantom ...