Events2Join

Is Device Removal Necessary after Fixed|Angle Locking Plate ...


Is Device Removal Necessary after Fixed-Angle Locking Plate ...

Background and Objectives: The aim of this study was to evaluate whether device removal in symptomatic patients following locking plate ...

Is Device Removal Necessary after Fixed-Angle Locking Plate ...

Results of this study showed that Device removal surgery in symptomatic patients following locking plate osteosynthesis of a proximal humerus fracture can ...

Benefits of hardware removal after plating - ScienceDirect.com

However, a new adequate trauma can create a new fracture independently if there is an implant in-situ or not. It is important to understand the complications ...

LOCKED PLATING - Orthopaedic Trauma Association

• Why Locking plates needed. • Advantages. • Hybrid fixation. • Indications ... of locking screw head but can allow for variable angle screw insertion.

The Current Status of Locked Plating: The Good, the Bad, and the Ugly

Four patients (18%) had pain at follow-up, 3 of which required implant removal. In a similar retrospective evaluation of LISS plate fixation for 103 distal ...

Pitfalls and limits of locking plates - ScienceDirect.com

Preoperative planning is required to determine the fracture reduction strategy and select the implants. The type of plate and the type of screws and their ...

Arthroscopic Removal of Symptomatic Proximal Humerus Locking ...

The purpose of this article is to describe a technique for removing proximal humerus locking plates arthroscopically. Although technically demanding, the ...

Plating - AO Surgery Reference

After fixation is complete, the plate will be in contact with the bone throughout its length, but will act as a spring, providing compression at the far cortex.

implant removal following internal fixation of distal radius fractures

Introduction: Volar plate fixation for distal radius fractures has become increasingly common over the past decade, and an increasing number require implant ...

Arthroscopic-Assisted Removal of Proximal Humerus Locking Plates ...

Despite being a successful procedure, it is not devoid of complications that often require hardware removal, capsular release, and adhesiolysis. It can be ...

VariAx® 2 Xpress Distal Radius Locking System - Stryker

Removal or revision of the device may be required sometime in the ... angle in the plate. Also, when used with the probe or drill, the device can ...

Small Fragment Locking Compression Plate (LCP®) System

device in a hole that will be needed immediately for plate fixation. However, the device may be removed and a screw inserted through the same plate hole. A ...

Difficulties encountered removing locked plates - RCSEng

Most of these complications are implant or surgeon related. Commonly, the most junior member of the team is given responsibility for implant removal at the end ...

Complication with Removal of a Lumbar Spinal Locking Plate - 2015

Conclusion. Anterior locking plates add significant stability to an anterior spinal fusion mass. However, removal of this hardware can be ...

Variable Angle Locking Hand System for Fracture Repair and ...

DISCLAIMER: The following steps are summarized and do not constitute full operative instruction. Please refer to the package insert(s) or other labeling ...

Removal of Locked Volar Plates After Distal Radius Fractures

One of the factors that can make removal of volar locking plates more complicated is cross-threading of the screw in the plate [20] . This can ...

Zimmer® Periarticular Proximal Tibial Locking Plate

create fixed-angle constructs for use in comminuted fractures or where ... be removed and reinserted for the screws to lock properly to the plate. NOTE ...

Large Fragment Locking Compression Plate (LCP®) Technique Guide

Also, if the chosen Combi hole is needed for placement of a locking screw, it is desirable to place the. Push-Pull Reduction Device in the conventional portion ...

Variable Angle Locking Hand System

Confirm screw placement and length using radiographic imaging. • Place remaining screws in the head and plate shaft as needed, depending on fracture pattern.

versus Variable-Angle Locking Screws for Distal Humerus ...

However, contouring the plate or making holes in it affects the biomechanical properties of the plate, which is not ideal. Also, lower-profile implants are ...