Background and Objectives: Navigation systems are designed to enhance surgical precision, improving patient outcomes and reducing the risk ...

Precision of Cup Positioning Using a Novel Computer Tomography ...

Conclusions: The navigation tool offers intra-operative guidance on notable precision in cup placement, thereby effectively mitigating the risk ...

Precision of Cup Positioning Using a Novel Computer Tomography ...

Conclusions: The navigation tool offers intra-operative guidance on notable precision in cup placement, thereby effectively mitigating the risk of cup ...

Accuracy of angle and position of the cup using computed ... - PubMed

The absolute spatial error of cup position was ≤ 2 mm for each axis, and the angle error was ≤ 2° for the angles of inclination and anteversion.

Accuracy of cup placement using computed tomography-based ...

In the navigation system, the CT-based navigation system (CTN) has been reported to be most accurate method of cup placement in PL-THA [12,14], however, to our ...

Validation of a Novel Method of Measuring Cup Orientation Using ...

The mean error in OA measurement of the acetabular cup between simultaneous orthogonal biplanar radiographic and CT imaging was 0.5° (SD: 1.9°, ...

Accuracy of Cup Positioning With the Computed Tomography-Based ...

The accuracy of cup positioning in CT-based 2D-3D matched navigation was better than in paired-point matched navigation, and was not affected by patient factors ...

Article Versions Notes - MDPI

Precision of Cup Positioning Using a Novel Computed Tomography Based Navigation System in Total Hip Arthroplasty. Medicina 2024, 60, 1589. https://doi.org ...

Measurement accuracy of the acetabular cup position using ... - Nature

Accurate cup placement is critical to ensure satisfactory outcomes after total hip arthroplasty. Portable hip navigation systems are novel ...

The accuracy and precision of acetabular implant measurements ...

3D-CT measurements were found to closely match the “true values” of the component position measurements, compared with the 2D-CT methods. ICC ...

Accuracy of augmented reality with computed tomography-based ...

This CT-based navigation system with AR enabled surgeons to place the cup more accurately than was possible by freehand placement during THA in ...

[PDF] Accuracy of cup position following robot-assisted total hip ...

Precision of Cup Positioning Using a Novel Computed Tomography Based Navigation System in Total Hip Arthroplasty · Engineering, Medicine. Medicina · 2024.

Accuracy of angle and position of the cup using computed ...

Using Stryker CT-based navigation, Iwana et al. [26] reported that the mean absolute error of the cup angle was 1.8° ± 1.6° for RI and 1.2° ± 1.1° for RA.

A novel positioner for accurately sitting the acetabular component

There were no statistically significant differences in the horizontal displacement between the two groups. The accuracy of cup inclination was ...

Accuracy of acetabular cup placement using an angle-adjusting ...

The novel acetabular cup alignment guide with a laser pointer is a simple tool that provides better accuracy of acetabular cup orientation than ...

Accuracy of acetabular cup placement using an angle-adjusting ...

The novel angle-adjusting alignment guide with laser pointer is a simple tool that provides better accuracy of cup position than that obtained using ...

Accuracy of Cup Positioning With the Computed Tomography-Based ...

The accuracy of various navigation systems used for total hip arthroplasty has been described, but no publications reported the accuracy of cup orientation ...

Comparison of accuracy of cup position using portable navigation ...

High accuracy in cup placement was achieved using accelerometer-based portable navigation in supine THA and using a navigation system may contribute to ...

Arthroplasty Today

Stem alignment determination using a 3D templating software program and computed tomography ... Improving cup positioning using a · mechanical ...

Accuracy of a novel accelerometer-based navigation (Naviswiss) for ...

Accuracy of angle and position of the cup using computed tomography- based navigation systems in total hip arthroplasty. Comput Aided Surg. 2013;18(5–6):187 ...