- Relationship between the Patients' Setup Errors with Dosimetric and ...🔍
- Dosimetric impact of setup errors in head and neck cancer patients ...🔍
- Assessment of dosimetric impact of interfractional 6D setup error in ...🔍
- View of Relationship between the Patients' Setup Errors with ...🔍
- Dosimetric Effects Of Interfractional Patient Setup Error On Target ...🔍
- Dosimetric effect of rotational setup errors in volumetric modulated ...🔍
- Dosimetric Effects of Setup Uncertainties on Breast Treatment Delivery🔍
- Dosimetric evaluation of patient setup errors due to uncertainties ...🔍
Relationship between the Patients' Setup Errors with Dosimetric and ...
Relationship between the Patients' Setup Errors with Dosimetric and ...
Conclusion: The radiobiologic parameters in IMRT were less sensitive to setup errors compared to FIF and CW techniques. The radiobiological parameters can help ...
Relationship between the Patients' Setup Errors with Dosimetric and ...
This study aimed to investigate the effect of the patients' setup errors on dosimetric and radiobiologic parameters for left-sided Whole-Breast Irradiation ( ...
Relationship between the Patients' Setup Errors with Dosimetric and ...
Keywords: Whole Breast Radiotherapy; Setup Errors; Intensity-Modulated Radiation Therapy; Field-In-Field;. Radiobiological Parameters. ORIGINAL ARTICLE. Page 2 ...
Relationship between the Patients' Setup Errors with Dosimetric and ...
Relationship between the Patients' Setup Errors with Dosimetric and Radiobiologic Parameters in Whole Breast Radiotherapy ...
Relationship between the Patients' Setup Errors with Dosimetric and ...
Conclusion: The radiobiologic parameters in IMRT were less sensitive to setup errors compared to FIF and CW techniques. The radiobiological parameters can help ...
Dosimetric impact of setup errors in head and neck cancer patients ...
Our study showed that the setup uncertainties if left uncorrected would result in significant decrease in target volume coverage and nonsignificant increase in ...
Assessment of dosimetric impact of interfractional 6D setup error in ...
The treatment plan was recalculated on the CBCTs with the rotation error (RError), translation error (TError), and translation plus rotation ...
View of Relationship between the Patients' Setup Errors with ...
Return to Article Details Relationship between the Patients' Setup Errors with Dosimetric and Radiobiologic Parameters in Whole Breast Radiotherapy Download ...
Dosimetric Effects Of Interfractional Patient Setup Error On Target ...
The purpose of this study is to quantify the dosimetric impact of inter-fractional patient setup error on planning target volume (PTV) coverage and maximal ...
Dosimetric effect of rotational setup errors in volumetric modulated ...
Setup errors are an important factor in the dosimetric accuracy of radiotherapy delivery. In this study, we investigated how rotational setup errors ...
Dosimetric Effects of Setup Uncertainties on Breast Treatment Delivery
Setup errors exceeding these values may cause large dosimetric changes for some patients, particularly those with larger hot or cold regions in the dose ...
Dosimetric evaluation of patient setup errors due to uncertainties ...
Then drawing the relation between X, Y and Z shift as a function of no. of fractions then average shift for all fractions calculated to be (0.05) cm, ( 0.08) cm ...
Dosimetric impact of rotational setup errors in volumetric modulated ...
In conclusion, rotational setup errors only slightly impact dose coverage during postoperative cervical cancer VMAT. However, the pitch setup ...
Dosimetric Consequences of Setup Errors for Patients with Head ...
Dosimetric Consequences of Setup Errors for Patients with Head and Neck Tumors in the Context of Daily Dose Verification ... Footnotes: Author Disclosure: J.
Dosimetric consequences of rotational setup errors with direct ...
However, the efficacy of radiotherapy can be compromised by errors in the treatment setup of the patient which affects the delivered radiation.
The dosimetric impact of daily setup error on target volumes and ...
Our dosimetric evaluation suggests significant underdosing with inaccurate target localization and emphasizes the importance of accurate patient setup and ...
The dosimetric impact of daily setup error on target volumes and ...
Our dosimetric evaluation suggests significant underdosing with inaccurate target localization and emphasizes the importance of accurate patient ...
Errors in radiation oncology: a study in pathways and dosimetric ...
As complexity for treating patients increases, so does the risk of error. Some publications have suggested that record and verify (R&V) systems may ...
Dosimetric consequences of rotational setup errors with direct ...
Ten patients with brain tumors who received intensity-modulated radiotherapy had dose distributions re-evaluated to assess the impact of systematic rotational ...
Dosimetric consequences of translational and rotational errors in ...
Simulation of RS without image-guidance reduced target coverage and conformity to 75% ± 19% and 60% ± 25% of planned values. Each 3D set-up ...