- Reliability and validity of knee angles and moments in patients with ...🔍
- Reliability and validity of knee joint angles and moments in patients ...🔍
- reliability and validity of knee joint angles and moments in patients ...🔍
- "Gait Real|Time Analysis Interactive Lab🔍
- Reliability and concurrent validity between two|dimensional and ...🔍
- Investigators at University of Western Ontario Target Osteoarthritis ...🔍
- Reliability and validity of pose estimation algorithm for measurement ...🔍
- Reliability of principal components and discrete parameters of knee ...🔍
Reliability and validity of knee angles and moments in patients with ...
Reliability and validity of knee angles and moments in patients with ...
Results suggest frontal and sagittal plane knee angles and moments in patients with knee OA evaluated using a treadmill-based system are reliable and valid.
Reliability and validity of knee angles and moments in patients with ...
Knee angles were very highly correlated between systems (r = 0.88−0.97, mean differences <1.00 degrees). Knee moments were less strongly correlated (r = 0.78− ...
Reliability and validity of knee joint angles and moments in patients ...
Conclusions: Although highly correlated, there are substantial differences in knee angles and moments between the treadmill-based and overground movement ...
Reliability and validity of knee angles and moments in patients with ...
Significance. Results suggest frontal and sagittal plane knee angles and moments in patients with knee OA evaluated using a treadmill-based system are reliable ...
Reliability and validity of knee joint angles and moments in patients ...
RELIABILITY AND VALIDITY OF KNEE JOINT ANGLES AND MOMENTS. IN PATIENTS WITH KNEE OSTEOARTHRITIS USING A TREADMILL-. BASED MOVEMENT ANALYSIS SYSTEM. R.F. Pinto ...
Reliability and validity of knee angles and moments in patients with ...
Request PDF | Reliability and validity of knee angles and moments in patients with osteoarthritis using a treadmill-based gait analysis system | Background ...
reliability and validity of knee joint angles and moments in patients ...
RELIABILITY AND VALIDITY OF KNEE JOINT ANGLES AND MOMENTS IN PATIENTS WITH KNEE OSTEOARTHRITIS USING A TREADMILL-BASED MOVEMENT ANALYSIS SYSTEM ...
"Gait Real-Time Analysis Interactive Lab: Reliability and Validity of ...
Conclusion: Preliminary results suggest adequate reliability and validity of knee angles and moments in patients using the GRAIL. Knee transverse plane measures ...
Reliability and concurrent validity between two-dimensional and ...
The results of this study indicate that the KASR and KSD are reliable and more highly correlated with 2D measures of frontal plane knee kinematics when compared ...
Investigators at University of Western Ontario Target Osteoarthritis ...
Investigators at University of Western Ontario Target Osteoarthritis (Reliability and validity of knee angles and moments in patients with ...
Reliability and validity of pose estimation algorithm for measurement ...
In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in ...
Reliability of principal components and discrete parameters of knee ...
Reliability and validity of knee angles and moments in patients with osteoarthritis using a treadmill-based gait analysis system. · Medicine, Engineering. Gait & ...
Knee angles and moments of patients with knee osteoarthritis ...
... Further research will now be necessary to assess the validity of the proposed index. The techniques to record and calculate knee moments differ among ...
Reliability and Validity of Goniometric Measurements at the Knee
A roentgenogram was taken of the extremity before the subject was moved. Pearson product-moment correlation coefficients (r's) and intraclass correlation ...
Peak knee joint moments accurately predict medial and lateral knee ...
Low to moderate correlations of R2 < 0.49 were detected except between KAM2 and latKCF2 (R2 = 0.68) for the patient group and KAM2 and medKCF2 ( ...
Validity and Reliability of a Wearable Goniometer Sensor Controlled ...
The knee flexion angle during gait was assessed using a wearable goniometer sensor and a standard optical motion analysis system. The ...
Does the 2D Frontal Plane Projection Angle Predict Frontal Plane ...
... angle can identify subgroups of patellofemoral pain patients who ... Validity and reliability of 2-dimensional trunk, hip, and knee ...
Test–retest reliability of the peak knee adduction moment during ...
The ICC suggests that the peak knee adduction moment is appropriate for use when distinguishing among patients, for example, in studies of ...
Accuracy and reliability of knee goniometry methods
Knee angles can be measured by traditional goniometers, smartphone apps are readily available and there are also purpose made digital devices.
Reliability of principal components and discrete parameters of knee ...
Discrete parameters and PC-scores from flexion angles and adduction moments had the highest ICC2,k values while adduction angles, rotation angles, and rotation ...