- Thermal Infrared Detection of Oil Film Thickness at Sea🔍
- thermal infrared detection of oil film thickness at sea🔍
- Quantitative Inversion Ability Analysis of Oil Film Thickness Using ...🔍
- Modeling of thickness dependent infrared radiance contrast of native ...🔍
- Overview of Research on Monitoring of Marine Oil Spill🔍
- Real|time Detection of Oil Slick Thickness Patterns with a Portable ...🔍
- A novel method for determination of the oil slick area based on ...🔍
- Optothermal evaluation of oil film thickness on water🔍
Thermal Infrared Detection of Oil Film Thickness at Sea
Thermal Infrared Detection of Oil Film Thickness at Sea - IEEE Xplore
Thermal Infrared Detection of Oil Film Thickness at Sea: Airborne and Portable Thermal Imagers are Used in One Experiment ; Electronic ISBN: 979-8-3503-2010-7.
Thermal Infrared Detection of Oil Film Thickness at Sea - IEEE Xplore
THERMAL INFRARED DETECTION OF OIL FILM THICKNESS AT SEA: AIRBORNE AND PORTABLE THERMAL IMAGERS ARE USED IN ONE. EXPERIMENT. Meiqi Wang1, Junfang Yang1 ...
Thermal Infrared Detection of Oil Film Thickness at Sea
... Infrared Detection of Oil Film Thickness at Sea: Airborne and Portable Thermal Imagers are Used in One Experiment | Find, read and cite all ...
thermal infrared detection of oil film thickness at sea - igarss 2023
2023 IEEE International Geoscience and Remote Sensing Symposium (IGARSS 2023), Pasadena, California, USA, 16 - 21 July, 2023.
Quantitative Inversion Ability Analysis of Oil Film Thickness Using ...
The results show that thermal infrared has good detection ability for OFT greater than 0.4 mm during the day, but weak detection ability for thinner oil films.
Modeling of thickness dependent infrared radiance contrast of native ...
An effective sensor needs to detect contrast between native and thin oil film covered sea surfaces. Optical techniques have been widely employed in ...
Overview of Research on Monitoring of Marine Oil Spill - IOPscience
... oil and sea water have been radiating thermal infrared ... infrared remote sensing are integratedly designed, the relative thickness of the oil film in seawater ...
Real-time Detection of Oil Slick Thickness Patterns with a Portable ...
imaging system could increase the thickness measurement range since heat radiance ... A LIDAR system for remote measurement of oil film thickness on sea surface.
A novel method for determination of the oil slick area based on ...
The oil slick regions of interest (ROI) are extracted with help of the thermal infrared image processing. Then, based on Principal Component Analysis (PCA) ...
Optothermal evaluation of oil film thickness on water
Photothermal techniques use a laser beam to thermally stimulate the surface of a sample while an IR detector monitors the surface temperature evolution which is ...
Identification of marine oil spill pollution using hyperspectral ...
With the addition of thermal infrared features, the oil type recognition results can better maintain the continuity of oil spill on the sea, ...
Thermal infrared intensity distribution of different oil products and...
Oil spills on the sea surface have caused serious harm to the marine ecological environment and coastal environment. Oil film thickness (OFT) is an important ...
Thermal Infrared Spectral Characteristics of Bunker Fuel Oil ... - MDPI
Remote sensing is an important method for monitoring marine oil-spill accidents. However, methods for measuring oil-film thickness remain insufficient.
The detection and prediction for oil spill on the sea based on the ...
Oil film is only half the heat capacity of water. The temperature gradient changes according to light conditions with heat exchange. In infrared images, “warm” ...
Infrared contrast of crude-oil-covered water surfaces
Infrared oil spill detection utilizes either temperature or emissivity contrast of native and oil-covered water surfaces. In particular, the thickness dependent ...
Thermal Infrared Spectral Characteristics of Bunker Fuel Oil ... - OUCI
Remote sensing is an important method for monitoring marine oil-spill accidents. However, methods for measuring oil-film thickness remain insufficient.
ARTICLE: “THERMAL-INFRARED SPECTRAL AND ANGULAR ...
In the visible and infrared region the spectral reflectance properties vary with oil type, emulsion level and film thickness [4], [7], and crude detection is ...
Combined Retrieval of Oil Film Thickness Using Hyperspectral and ...
An outdoor experiment was conducted to measure the thickness of oil films (0~3000 μm) using an airborne hyperspectral imager and thermal infrared imager, ...
Quantitative Inversion Ability Analysis of Oil Film Thickness Using ...
bright temperature difference machine learning oil film thickness inversion oil spill amount estimation thermal infrared remote sensing; NAICS/Industry Codes ...
Combined Retrieval of Oil Film Thickness Using Hyperspectral and ...
Furthermore, the feasibility of using hyperspectral and thermal infrared remote sensing to detect water-in-oil emulsions of different ...