Events2Join

Trephine reamer for use in removal of a femoral component of a hip ...


Trephine reamer for use in removal of a femoral component of a hip ...

The present application is directed to a hollow trephine reamer for use in cutting the femur for removing a portion or entirety of a femoral component of a hip ...

Utility of trephine reamers in revision hip arthroplasty - PubMed

Powered trephines used over a femoral component to disrupt the bone component interface can yield acceptable clinical and radiographic outcomes.

Management of a broken modular femoral stem following total hip ...

Using a trephine reamer to extract a broken femoral stem is a safe technique that preserves the femoral cortical integrity postoperatively in comparison with ...

DePuy Trephine Reamers - AZ Ortho

Non-sterile single use trephine reamers. Used with Moreland Cementless Hip ... DePuy Moreland Nicholls Hip Extraction Adapter · DePuy Universal Head ...

Use of a Trephine to Extract a Fractured Corail Femoral Stem During ...

Trephine coring reamers are a well-documented method used as an additional tool to remove firmly implanted widely porous-coated and fractured ...

Previously Unreported Complication of Trephine Reamers in ...

The use of trephine reamers aids extraction of femoral components in revision hip surgery as they allow for the safe disruption of the implant-bone.

MPR Trephine Reamers - Medical Products Resource

Non-sterile, single use trehpine reamers, for revision/extraction procedures. May be used in conjunction with driver shaft/slap hammer for power reaming.

Utility of Trephine Reamers in Revision Hip Arthroplasty

Powered trephines used over a femoral component to disrupt the bone component interface can yield acceptable clinical and radiographic outcomes while ...

Previously Unreported Complication of Trephine Reamers in ...

Trephine reamers have been used in revision total hip arthroplasty to facilitate the removal of femoral prostheses without creating additional osteotomy sites.

Minimally invasive hollow trephine technique is recommended for ...

Revision hip arthroplasty with a short femoral component in ... A new strategy to remove broken femoral mega- prostheses with hollow trephine reamers.

Arcos® Modular Femoral Revision System - Zimmer Biomet

stem. Sectioning the stem and utilizing trephine reamers can assist in the removal of the porous coated distal segment of a cementless stem (Figure 5).

MPR Trephine Reamers - MPR Orthopedics

Non-sterile, single use trehpine reamers, for revision/extraction procedures. May be used in conjunction with driver shaft/slap hammer for power reaming.

Management of a Broken Modular Femoral Stem Following Total ...

A trephine reamer was used to extract the stem during revision arthroplasty. Two years post-operative follow up showed improved Harris hip score ...

Minimally invasive hollow trephine technique is recommended for ...

Management of a broken modular femoral stem following total hip arthroplasty in a patient with sickle cell disease using an endofemoral trephine reamer: A case ...

Trephine Reamer Saw, 8" x 23 mm - 430123 - Grayline Medical

Designed for reaming around a stem of a femoral component implanted in a femur; For use in femoral revision procedures ...

Innomed Hip Instruments — surgical tools – other useful instruments

Designed with a delrin pad to help protect the femoral stem trunnion while removing the femoral head during anterior approach total hip revision arthroplasty ...

Arcos® Modular Femoral Revision System - Zimmer Biomet

Sectioning the stem and utilizing trephine reamers can assist in the removal ... between these and utilize the last reamer used to ream deeper into the femur.

Utility of Trephine Reamers in Revision Hip Arthroplasty

Background Extended trochanteric osteotomy (ETO) has proved to be an effective technique in complicated stem removal in femoral aseptic loosening or ...

Management of a broken modular femoral stem following total hip ...

Management of a broken modular femoral stem following total hip arthroplasty in a patient with sickle cell disease using an endofemoral trephine reamer: A case ...

Simple drilling technique for the removal of fractured femoral stem

∙ Klein, G.R. ∙ Pollice, P.F.. Previously unreported complication of trephine reamers in revision total hip arthroplasty. J Arthroplasty. 2006 Feb; 21:299-300.