- Upconversion|based lidar measurements of atmospheric CO 2🔍
- Upconversion|based lidar measurements of atmospheric CO2🔍
- [PDF] Upconversion|based lidar measurements of atmospheric CO2.🔍
- Airborne lidar measurements of atmospheric CO 2 column ...🔍
- Upconversion|based Lidar Measurements of Atmospheric CO _2🔍
- Pulsed airborne lidar measurements of atmospheric CO2 column ...🔍
- Airborne lidar measurements of atmospheric CO2 column ...🔍
- Atmospheric carbon dioxide profile detection with a continuous ...🔍
Upconversion|based lidar measurements of atmospheric CO 2
Upconversion-based lidar measurements of atmospheric CO 2
The upconversion module are built as a compact, robust and portable unit consisting of a 20 mm PPLN crystal placed in a 1064 nm cavity, to achieve high mixing ...
Upconversion-based lidar measurements of atmospheric CO2
For the first time an upconversion based detection scheme is demonstrated for lidar measurements of atmospheric CO2-concentrations, with a hard target at a ...
Upconversion-based lidar measurements of atmospheric CO2
For the first time an upconversion based detection scheme is demonstrated for lidar measurements of atmospheric CO 2 -concentrations, ...
(PDF) Upconversion-based lidar measurements of atmospheric CO2
Abstract and Figures. For the first time an upconversion based detection scheme is demonstrated for lidar measurements of atmospheric CO2- ...
Upconversion-based lidar measurements of atmospheric CO2 - DTU
Upconversion-based lidar measurements of atmospheric CO2. Høgstedt, Lasse; Fix, Andreas; Wirth, Martin; Pedersen, Christian; Tidemand-Lichtenberg, Peter.
Upconversion-based lidar measurements of atmospheric CO2
For the first time an upconversion based detection scheme is demonstrated for lidar measurements of atmospheric CO2-concentrations, with a hard target at a ...
Upconversion-based lidar measurements of atmospheric CO2
The return signal of an integrated path differential absorption lidar for atmospheric CO2 measurements at 1572 nm was shifted to 635 nm by upconversion ...
[PDF] Upconversion-based lidar measurements of atmospheric CO2.
It is for the first time analyzed how the field-of-view of a receiver system, for long range detection, depends critically on the parameters for the ...
Airborne lidar measurements of atmospheric CO 2 column ...
We measured the column-averaged atmospheric CO 2 mixing ratio (XCO 2 ) to a variety of cloud tops with an airborne pulsed multi-wavelength integrated path ...
Upconversion-based Lidar Measurements of Atmospheric CO _2
The return signal of an integrated path differential absorption lidar for atmospheric CO2 measurements at 1572 nm was shifted to 635 nm by upconversion ...
Pulsed airborne lidar measurements of atmospheric CO2 column ...
(2004) have developed and demonstrated a ground-based range-resolved CO2 backscatter profiling lidar, using a CO2 line near 2050 nm, a pulsed Ho:Tm:YLF laser ...
Airborne lidar measurements of atmospheric CO2 column ...
In 2016, we replaced the photomultiplier-based photon-counting receiver with a much more sensitive HgCdTe avalanche photodiode (APD)-based.
Upconversion-based lidar measurements of atmospheric CO2 - OUCI
Upconversion-based lidar measurements of atmospheric CO2. https://doi.org/10.1364/ee.2016.em4a.5 · Full text. Journal: Light, Energy and the Environment, 2016.
Atmospheric carbon dioxide profile detection with a continuous ...
We demonstrated a 1.57 μm continuous-wave differential absorption lidar (CW-DIAL) for atmospheric CO 2 profile detection based on the Scheimpflug imaging ...
Upconversion-based lidar measurements of atmospheric CO_2 - OUCI
Upconversion-based lidar measurements of atmospheric CO2. Andreas Fix, Lasse Høgstedt, Christian Pedersen, Peter Tidemand-Lichtenberg, Martin Wirth. https ...
Frequency-doubled CO2 lidar measurement and diode laser ...
A lidar instrument based on pulsed frequency-doubled carbon-dioxide lasers has been used at 4.88 microns for remote sensing of atmospheric carbon dioxide.
A 1.57μm DIAL lidar system for range resolved measurements of ...
We describe a lidar system based on erbium doped fiber amplifiers, designed to make range resolved measurements of CO 2 within the lower atmosphere at very ...
Remote Measurements of Industrial CO2 Emissions Using a Ground ...
Measurement of Atmospheric CO2 Column Concentrations Based ... Backscatter 2-μm Lidar Validation for Atmospheric CO2 Differential Absorption Lidar Applications.
Measuring Atmospheric CO2 Enhancements From the 2017 British ...
During the summer 2017 ASCENDS/ABoVE airborne science campaign, the NASA Goddard CO2 Sounder lidar overflew smoke plumes from wildfires in ...
A XCO2 Retrieval Algorithm Coupled Spatial Correlation for the ...
We describe the approach to estimating the atmospheric carbon dioxide (CO 2 ) for the Aerosol and Carbon Detection Lidar (ACDL) onboard the ...