- Large Fragment Locking Compression Plate 🔍
- PediLoc® Locking Cannulated Blade Plate🔍
- Variable Angle Locking Hand System🔍
- Arthroscopic|Assisted Removal of Proximal Humerus Locking Plates ...🔍
- VariAx® 2 Xpress Distal Radius Locking System🔍
- A New Locking Plate for Unstable Fractures of the Proximal Humerus🔍
- Complications after volar plate synthesis for distal radius fractures in🔍
- Appropriately Matched Fixed|Angle Locking Plates Improve Stability ...🔍
Is Device Removal Necessary after Fixed|Angle Locking Plate ...
Large Fragment Locking Compression Plate (LCP®) Technique Guide
Also, if the chosen Combi hole is needed for placement of a locking screw, it is desirable to place the. Push-Pull Reduction Device in the conventional portion ...
PediLoc® Locking Cannulated Blade Plate - OrthoPediatrics
Routine removal of internal fixation devices after ... device may be necessary . The ... Do not reuse . CAUTION: The device is not approved for screw.
Variable Angle Locking Hand System
plate cutter head, if deburring is needed after cutting. Plate Cutter for 1.3 mm to 2.0 mm Plates (03.130.271). The Plate Cutter for Plates is designed to cut ...
Arthroscopic-Assisted Removal of Proximal Humerus Locking Plates ...
Although further research is needed to determine the optimal time for ROH, the benefits of improved pain and ROM outweigh the risks in most cases. Limitations.
VariAx® 2 Xpress Distal Radius Locking System - Stryker
Removal or revision of the device may be ... angle in the plate. Also, when used with the ... When drilling locking holes, using the provided drill guide for screw ...
A New Locking Plate for Unstable Fractures of the Proximal Humerus
It is based on the principle of locking compression plates,6 is formed to the anatomy of the lateral proximal humerus, is attached with fixed-angle screws in ...
Complications after volar plate synthesis for distal radius fractures in
Plate removal carried out at the patient's request without explanation was not included in the complication count. The analysis was performed ...
Appropriately Matched Fixed-Angle Locking Plates Improve Stability ...
These findings suggest that optimally matching the volar locking plate width to the radius may provide advantages for stability of the fixation ...
Titanium Volar Distal Radius Plating System - Arthrex
and sliding the plate proximal or distal, if necessary ... fixed angle locking constructs. After drilling ... The threaded Plate Elevator can be used as an ...
A.L.P.S.® Hand Fracture System Surgical Technique - Zimmer Biomet
When shortening with the benders, it is recommended that you straddle the bridge to be removed with the benders and simply bend toward the bottom of the plate ...
Locking versus Non-locking Neutralization Plates with Limited ...
They represent about 3-10% of all tibial fractures [1]. Intramedullary nail fixation for most fractures is still the gold standard [2], but if ...
Long-term Results of Dorsally Displaced Distal Radius Fractures ...
Long-term Results of Dorsally Displaced. Distal Radius Fractures Treated With the. Pi-Plate: Is Hardware Removal Necessary? MINOS E. TYLLIANAKIS, MD; ANDREAS M.
Open reduction, pediatric hip locking plate - AO Surgery Reference
Implants in young children should always be removed to prevent them from being covered by bony overgrowth. Implant removal is not compulsory in adolescents. All ...
Variable Angle Locking Anterior Patella Plate 2.7
tions for use do not include all the information necessary for selection and use of a device. Please read the instructions for use and the ...
2.7 mm Locking T Plate 3 Head Holes Uses & Sizes - Vast Ortho
While the surgeon must make the final decision on implant removal, we recommend that whenever possible and practical for the individual patient, fixation ...
2.7 mm Variable Angle Locking Calcaneal Plating System
Optional instrument. 309.520. Conical Extraction Screw, for 2.7 mm and 3.5 mm Cortex screws ... Exposure and mobilization of the peroneal tendons is necessary for ...
Point-Counterpoint: Are Locking Plates Necessary For First MPJ ...
With locked plating, the plate and not the bone is pre-stressed. Unicortical fixation helps preserve the blood supply and reduces screw-induced stress in bone.
Biomechanics of Locked Plates and Screws - Orthobullets
increases the potential for refracture after device removal; and ... Much like other fixed-angle devices, when locked ... the friction fit between the plate and the ...
Elective implant removal in symptomatic patients after internal ...
After plate fixation, implant related complications e.g. impingement and meteorosensitivity can influence these clinical outcome parameters. It ...
Arthroscopic-Assisted Removal of Proximal Humerus Locking Plates ...
The findings of this study confirm our hypothesis that elective arthroscopic plate removal after ORIF of proximal humerus fractures leads to ...