Liability of Employed Engineers

In all cases, the issue of who signs or seals the drawings, plans, or specifications is not necessarily relevant to whether the engineer and/or the firm will be ...

Errors and Omissions in Contract Documents: What to Expect

If your contractor discovers an error or omission in the contract documents, they will request a clarification from the architect. Your ...

Do Contractors Need Professional Liability Insurance?

... errors or omissions in design have shifted to the construction manager and its subcontractors. General liability policies carried by ...

Shop Drawings 101: What Subcontractors Need to Know - Billd

If a shop drawing lacks a review stamp, it must be immediately returned to the contractor, as it is their responsibility if problems arise due ...

A Guide to Rights and Obligations under Design Contracts

These requirements primarily apply to contractors, as they are the ones that are liable for the quality of the materials installed in a building ...

Is the Contractor liable for the Employer's design being incomplete ...

Further, the Employer once notified will review the “…error, fault or other defect…“, within the “Employer's Requirements” and will determine whether the same ...

ARCHITECTS' AND ENGINEERS' LIABILITY UNDER IOWA ...

Contractors will further argue that they assume and ... 1993) (holding with a majority of jurisdictions that design professionals are liable to third party ...

Keep Coverage in Play and Limit Your Architect's Exposure

Do not allow edits this section such as those below because they create liability for an architect for a contractor's errors, which can jeopardize cov-.

Protecting Design-Build Owners through Design Liability Coverage ...

errors and omissions insurance policies, design-build owners can examine ... 12" Thus, the situa- tion can arise where an owner's construction manager will not be ...

How Engineers Can Inadvertently Extend Their Liability

Most engineers understand that if they commit errors or omissions that result in damages, they may face claims from their clients. However, ...

Architects Liability in Using Other Architects Drawings

If the first design professional has completed the scope of their contract, drawings should be stamped by them. If they have not completed their design, then ...

Florida Construction Laws On Design Professional Liability

Any errors, omissions, or oversights in these areas can spell major trouble, especially since general contractors and lower tier subcontractors ...

Take the fifth: Liability for design mistakes | Comment | Building

It used to be said that designers were under a continuing duty to review their designs up until practical completion. Thus, they would continue ...

Design Problems in the Construction Industry - Raken

While designers can do their best to avoid errors, it's not always possible. Once you are aware of the most common construction design issues, ...

The Twelve Deadly Sins: An Owner's Guide to Avoiding Liability for ...

maintaining that the contractor knew or should have known about the typographical error. ... ed plans and drawings provided to contractors bidding on public.

What is design-build & what does it mean for subcontractors?

No matter who leads the project, contractors will have significant influence in the design process; the goal is to draw on contractor experience ...

Construction Drawings vs Shop Drawings - Key Differences

Liabilities and risks during drafting and submission process for these drawings · Construction drawings are labeled “Not for Construction” to ...

#43: See No Evil: The Design Professional's Liability for ...

If a reasonably careful design professional would have spotted a defect, failure to catch it is negligence. Proving that a design professional ...

liability of design professionals for the review/approval of contractor ...

Courts will not hold design professionals accountable for errors in dimensions and quantities on the contractor's shop drawings. Was the review timely ...

"Contractor to verify in the field... Architect not responsible" is this not ...

There should never be any questions regarding discrepancies on the drawings if the architects would do their job for once. ... It reduces errors ...